Important: Configuring the hardware RAID card erases Mac OS X Server on theTo set up a RAID array in Mac OS X, follow these steps: From the RAID tab of Disk Utility, click and drag the disks from the list at the left to the Disk.This article is about the data storage technology. You must configure the card and drive modules to use its RAID features. The Hardware RAID PCI Card ‘s default configuration is JBOD mode (for just a bunch of disks) in which each drive module is presented as an independent drive with no RAID configured.Load the Installation CD, open the Mac RAIDar Setup folder and double-click SetupMac.dmg to start the installation. Bear in mind that even though other platforms might be suitable, it. Run the available setup, and follow all displayed instructions to complete the process. However, make sure to confirm that your computer configuration is supported by this release before any utility is installed on it. For other uses, see Raid (disambiguation).CalDigit T4 RAID Storage Utility 1.0.41 for Mac OS.This was in contrast to the previous concept of highly reliable mainframe disk drives referred to as "single large expensive disk" (SLED). Alternatively, you can install a RAID ( / r eɪ d/ " Redundant Array of Inexpensive Disks" or " Redundant Array of Independent Disks" ) is a data storage virtualization technology that combines multiple physical disk drive components into one or more logical units for the purposes of data redundancy, performance improvement, or both. Double-click the icon and follow the installer instructions to install RAIDar.
Setup Raid Configuration Utility Mac OS X ServerRAID levels greater than RAID 0 provide protection against unrecoverable sector read errors, as well as against failures of whole physical drives. Each scheme, or RAID level, provides a different balance among the key goals: reliability, availability, performance, and capacity. The different schemes, or data distribution layouts, are named by the word "RAID" followed by a number, for example RAID 0 or RAID 1. ![]() A similar approach was used in the early 1960s on the IBM 353. Around 1988, the Thinking Machines' DataVault used error correction codes (now known as RAID 2) in an array of disk drives. At IBM filed a patent disclosing what was subsequently named RAID 5. Around 1983, DEC began shipping subsystem mirrored RA8X disk drives (now known as RAID 1) as part of its HSC50 subsystem. For this configuration to provide a significant speed advantage an appropriate controller is needed that uses the fast SSD for all read operations. For example, a fast SSD can be mirrored with a mechanical drive. RAID can also provide data security with solid-state drives (SSDs) without the expense of an all-SSD system. Most use simple XOR, but RAID 6 uses two separate parities based respectively on addition and multiplication in a particular Galois field or Reed–Solomon error correction. Overview Many RAID levels employ an error protection scheme called " parity", a widely used method in information technology to provide fault tolerance in a given set of data. The benefit of RAID 0 is that the throughput of read and write operations to any file is multiplied by the number of drives because, unlike spanned volumes, reads and writes are done concurrently. In comparison, a spanned volume preserves the files on the unfailing drives. But because striping distributes the contents of each file among all drives in the set, the failure of any drive causes the entire RAID 0 volume and all files to be lost. Compared to a spanned volume, the capacity of a RAID 0 volume is the same it is the sum of the capacities of the drives in the set. RAID levels and their associated data formats are standardized by the Storage Networking Industry Association (SNIA) in the Common RAID Disk Drive Format (DDF) standard: RAID 0 consists of striping, but no mirroring or parity. Standard levels Storage servers with 24 hard disk drives each and built-in hardware RAID controllers supporting various RAID levelsOriginally, there were five standard levels of RAID, but many variations have evolved, including several nested levels and many non-standard levels (mostly proprietary). Color finale pro mac torrentWrite throughput is always slower because every drive must be updated, and the slowest drive limits the write performance. Actual read throughput of most RAID 1 implementations is slower than the fastest drive. Sustained read throughput, if the controller or software is optimized for it, approaches the sum of throughputs of every drive in the set, just as for RAID 0. If a request is broadcast to every drive in the set, it can be serviced by the drive that accesses the data first (depending on its seek time and rotational latency), improving performance. Thus, any read request can be serviced by any drive in the set. Data is written identically to two or more drives, thereby producing a "mirrored set" of drives. This level is of historical significance only although it was used on some early machines (for example, the Thinking Machines CM-2), as of 2014 it is not used by any commercially available system. Hamming-code parity is calculated across corresponding bits and stored on at least one parity drive. All disk spindle rotation is synchronized and data is striped such that each sequential bit is on a different drive. RAID 2 consists of bit-level striping with dedicated Hamming-code parity. The main advantage of RAID 4 over RAID 2 and 3 is I/O parallelism: in RAID 2 and 3, a single read I/O operation requires reading the whole group of data drives, while in RAID 4 one I/O read operation does not have to spread across all data drives. This level was previously used by NetApp, but has now been largely replaced by a proprietary implementation of RAID 4 with two parity disks, called RAID-DP. Although implementations exist, RAID 3 is not commonly used in practice.RAID 4 consists of block-level striping with dedicated parity. Parity is calculated across corresponding bytes and stored on a dedicated parity drive. All disk spindle rotation is synchronized and data is striped such that each sequential byte is on a different drive. ![]() As with RAID 5, a single drive failure results in reduced performance of the entire array until the failed drive has been replaced. RAID 6 requires a minimum of four disks. This makes larger RAID groups more practical, especially for high-availability systems, as large-capacity drives take longer to restore. Double parity provides fault tolerance up to two failed drives. Rebuilding an array requires reading all data from all disks, opening a chance for a second drive failure and the loss of the entire array.RAID 6 consists of block-level striping with double distributed parity. Like all single-parity concepts, large RAID 5 implementations are susceptible to system failures because of trends regarding array rebuild time and the chance of drive failure during rebuild (see " Increasing rebuild time and failure probability" section, below). The elements of a RAID may be either individual drives or arrays themselves. Nested (hybrid) RAID In what was originally termed hybrid RAID, many storage controllers allow RAID levels to be nested. RAID 10 also minimizes these problems. The larger the drive capacities and the larger the array size, the more important it becomes to choose RAID 6 instead of RAID 5. If a single drive failure occurs then one of the mirrors has failed, at this point it is running effectively as RAID 0 with no redundancy. RAID 0+1: creates two stripes and mirrors them. When the top array is RAID 0 (such as in RAID 1+0 and RAID 5+0), most vendors omit the "+" (yielding RAID 10 and RAID 50, respectively). The final array is known as the top array.
0 Comments
Leave a Reply. |
Details
AuthorAustin ArchivesCategories |